(657) 777-3411
HOME
PRODUCTS
MANUFACTURERS
SERVICES
ABOUT US
LOCATIONS
CREDIT
CONTACT US
BACK TO 48WS
BROWSE CATEGORIES
> Bolt
> Nail
> Nut
> Screws
> Staple
> Washer
Adhesives | Sealants | Tape
Air & Pneumatic Tools
Automotive | Fleet | Vehicle Maintenance
Construction Fabrics
Decorative Concrete
Diamond Products
Electronics | Batteries
Equipment
Erosion Control | SWPPP
Fastening Pins & Inserts
Food Service
Furniture
Hardware Supplies
Hospitality
Hydraulic Products
Industrial Motors and Engines
Industrial Pumps
Laboratory Products
Ladders | Platforms | Scaffolding
Leveling | Measuring | Surveying
Lifting Equipment
Lubrication | Oils | Grease
Machining Supplies
Material Handling | Storage | Containment
Office Supplies
Outdoor Products
Phoenix Support Systems
Plumbing Supplies
Power Tool Accessories
Power Transmission Products
Presses & Shop Equipment
Rebar and Wire Mesh
Refrigeration | HVAC | Air Treatment | Etc.
Rental Equipment
Safety Equipment and Products
Saw Blades
Security Equipment and Accessories
Shop Vacuums
Sports Drinks and Thirst Quenchers
Strapping
Structural Hardware
Strut, Channel, & Fittings
Testing Instruments for all Purposes
Tool Storage | Job Site Boxes | Truck Boxes | Transfer Tanks
Trench Drains
Waterproofing Products
Welding Products and Equipment
Home
/
Categories
/
Safety Equipment and Products
/
Gas Detection
/
Automated Gas Detector Test Systems
/
Search:
Intelligent Gas Detector
GD-70D Series
RKI Instruments
The new Model GD-70D smart gas detection transmitter series sets a new standard for performance, flexibility, and versatility. The GD-70D sample-draw transmitter offers an array of sensor technologies unmatched in the industry, including unique offerings, such as our hydrogen-specific or LEL versions. The long life high capacity pump and wide variety of sensing elements are replaceable in a few seconds, with no tools required! The smart sensors retain all calibration and sensor-specific data in non-volatile memory, so sensors can be hot-swapped in the field with no programming required. The sensors also retain calibration information, which means they can be conveniently calibrated separate from the transmitter, avoiding transport of calibration gases to the field location. The GD-70D firmware automatically corrects for long-term zero and span “drift” minimizing maintenance and maximizing reliability. The GD-70D can be used as a stand-alone device, offering a number of communication protocols to existing PLC systems, or can be integrated with RKI’s Beacon series of single and multi-channel controllers. All GD-70D transmitters include a large, easy to read integral LCD display, tri-color bar graph for visual notification of alarm status, programmable low and high alarm relays, and fault relay. Pump flow is self-tuning for maintenance-free operation. Because all GD-70D base units are identical, sensors can be interchanged with no programming or tools required, resulting in maximum flexibility to the user.
(click image to enlarge)
Quick Overview
Monitor combustibles, O2, and a wide range of toxics Plug and play smart sensors retain calibration and sensor data Common platform (Main unit / Sensor / Pump) for all detection methods Universal main unit (all sensor types) Multifunctional sensor unit (New Intelligent sensor) No internal tubing (main unit) / No coil (pump) Front access, no tool required, easy sensor and pump replacement Large size LCD screen Various communication methods available (4-20mA, NT and PoE) Minimal maintenance cost through enhanced troubleshooting firmware functions Small mounting space Environmentally friendly Wide variety of sensors available
Interested in this item or want more information?
Phone:
Email:
Can't find what you want? Give us a call and we can help you find it.
Details
MAIN UNIT
Model
GD-70D
GD-70D-NT
GD-70D-ET
Communication
4-20mA DC
DC power line communication
PoE Method
Detection principle
Different type depending upon sensor unit and detectable gas (see table)
Sampling method
Sample drawing types (auto-adjustment of flow rate) 0.5 / min +/-10%
Display
Large LCD display (white backlight)
Gas concentration
Flow rate, communication status, Pyrolyzer status, gas detectored
Error code, content of error
Gas alarms
Two alarm levels: 1st alarm - Red
2nd alarm - Red
Fault alarm: Yellow
External output
1st, 2nd, and trouble alarms : Relay contact output for each alarm
Self diagnostic function
System failure, sensor failure, flow failure, communication error NT / ET / Analog
Datalogging
Event history, alarm history, calibration history. Alarm trend (180 sec before / after 1st alarm)
Operation temp. & humidity
0 ~ 40ºC, 30 ~ 70% RH (non-condensing)
Operating settings
All operational settings are user adjustable through front panel
Power requirements
DC 24V+/- 10%, approx 1.5W (Max 4W including sensor unit) Note: Approx. 2.5W (Max 5W) with SGU sensor unit
PoE standard arrangement
Dimensions
2.8”W x 4.7”H x 5.9”D (70W x 120H x 150Dmm)
Weight
Approx. 0.9kg (2.0lbs), including sensor unit
Mounting
Wall-mounting base plate by 2 or 3 screws
Sampling tubing
4 x 6mm PTFE tubing recommended. Tube fittings provided as standard accessories
Bushing
Cable type varies depending on communication method (Cable bushing optional)
SENSOR UNIT
Model
ESU
SGU
SSU
OSU
NCU
Detection Principle
Electro-chemical cell
Semi-conductor
Pyrolysis-particle
Galvanic cell
Catalytic combustion
Gas detected and detection range
Refer to list of detectable gases
0-2000ppm H2, CH4, or CH2F2
(R-32) in air and others
0-15ppm TEOS in air
0-25% O2 in air
0-100% LEL H2, CH4, and others
Self diagnosis function
Sensor trouble, system failure
Date logging function
Event history, alarm history, calibration history, Alarm trend (60 sec. before/after 1st alarm)
PYROLYSER UNIT
Model
PLU-70
Application
NF3 / TEOS gases detected in air
Usage
Used by connecting to “GD-70D” (Main unit)
Power Lamp
LED (Green color)
Normal: Light-on
Warming-up: Flashing at every 1 sec interval
Trouble: Flashing at every 0.2 sec interval
Self-diagnostic function
Pyrolyser unit trouble
Fan Trouble
System trouble
Operating temp. & humidity
0-40° C, 30-70% RH (non-condensing)
Operational settings
All operational settings are user adjustable through front panel.
Power requirements
DC 24V+/- 10%, approx. 25W (max)
Dimensions
2.8”W x 4.7”H x 5.9”D (70W x 120H x 150Dmm)
Weight
Approx. 1.2kg (2.6lbs)
Mounting
Wall-mounting base plate by 2 or 3 screws
Sampling
4x6mm PTFE tubing recommended. Tube fittings provided as standard accessories
Bushing
1.25sq 2 core cable for power supply DC24V (Cable bushing optional)
Additional Information
Manufacturer: RKI Instruments